Resistance Current Voltmeter Signal Generator Process Calibrator 4-20mA LB02
$ 73.04
- Description
- Size Guide
Description
Resistance Current Voltmeter Signal Generator Source Process Calibrator 4-20mA/0-10V/mV LB02Description :
This instrument can output/measurement the following signals:Current signal/Voltage signal/mV signal;8 kinds of thermocouple(E,K,B,S,T,R,J,N) signal;Resistance signal;Thermal resistance(Pt100,Cu50)signal,containing 14 input,15 output,analog meter site can be read or the vast majority of quantities.V,mV,mA, Ω input and output has a corresponding button,call directly,no combination of keys,quick and easy operation.Small instrument,Rich functionality
Features :
1. Expect with the conventional signal input and output functions,as well as resistance,Pt100,Cu50 RTD,thermocouple input-output 8 kinds of signals,very powerful
2. All functions all use internal electronic switch,and some other brands on the market,unlike DIP switch auxiliary products need to exclude the impact of the mechanical structure life,but also improves the ease of use
3. Two connector terminals,any level,regardless of the input and output terminals of the full use of these two,no longer have to forget plug lead damage to the meter or equipment to worry about
4. V,mV,mA, Ω input and output has a corresponding button,call directly,without advance menu selection,thermocouple,RTD input and output it is only after entering the function corresponding mV or Ω files left a r r o w or right a r r o w to select it,the operation is very simple,no combination of keys,quick and easy operation
5. Segment LCD clear display and used multimeter or a calculator is the same.Large display area,visual area of 49*29mm.Low power consumption,maximum power consumption of less than 0.3mA.It will be less than 10mA,when the backlight is opened
Update Feature :
1. Increase disposable fast blow fuse, to avoid false instrument damage caused by voltage 220V plug
2. In addition to having a conventional signal input and output functions, as well as resistance, PT100.Cu50 RTD, thermocouple eight kinds of input and output signals can be output, measuring negative temperature, very powerful
3. Thermal resistance, resistance to external excitation output current is reduced sensitivity. Increase the output and the measurement accuracy. For both constant and non-constant resistance measurement method, expanding the use of the instrument
4. All functions all use internal electronic switch
5.V.mV.mA. Resistance of the input and output has a corresponding button, directly call without advance menu, no combination of keys
6. Only two connector terminals, any level, regardless of the input and output all use these two terminals;
Measure performace index :