-40%

Hi-accuracy 0.02% Current & Voltage Process Calibrator with Frequency Source

$ 285.12

Availability: 100 in stock
  • Brand: generic
  • MPN: etx-2015
  • All returns accepted: Returns Accepted
  • Return shipping will be paid by: Buyer
  • Restocking Fee: No
  • Country/Region of Manufacture: China
  • Model: etx-2015
  • Refund will be given as: Money Back
  • Condition: New
  • Item must be returned within: 30 Days

    Description

    Note: we'll ship this item via
    express mail service
    to
    USA, Canada, Australia,
    New Zealand, Ireland, Austria, Belgium, Denmark, Germany, France, Finland, Luxemburg,
    Malta, Norway, Sweden, Swiss, Spain, Italy, UK, Japan, Korea,Thailand, Malaysia, Indonesia,
    Philippine, Singapore.
    Clients from other countries pls contact us in advance to confirm different shipping charges
    before you order.
    ETX-2015
    Function:
    1. Source of voltage, current and frequency.
    2. Measure of voltage, current, loop current and frequency.
    3. Manual stepping and automatic stepping and ramping.
    4. Support for PC communication.
    Summary of Source and Measure Functions
    :
    Function
    Measure
    Source
    DC V
    0-30 V
    0-10 V
    DC mV
    0-100 mV
    0-100 mV
    DC mA
    0-24 mA
    0-24 mA
    Frequency
    1.000Hz-99.999kHz
    0.00Hz-20.000kHz
    Others
    24V power supply, Step, Ramp.
    Specifications
    :
    Specifications are based on a one year calibration cycle and apply from +18
    C
    to +28
    C
    unless stated otherwise.
    All specifications assume a 10 minute warmup period.
    1. DC Voltage Measurement
    Range
    Maximum measurement range
    Resolution
    Accuracy (% of reading + Counts)
    ETX-1815
    ETX-2015
    30V
    0V-31V
    0.001V
    0.05+2
    0.02+2
    100mV
    -15mV-80mV
    0.001mV
    0.05+20
    0.02+20
    80mV-125mV
    0.01mV
    0.05+2
    0.02+2
    -10
    C
    -18
    C
    , +28
    C
    -55
    C
    temperature coefficient,±0.005%FS/
    C
    .
    Input resistance: >1MΩ.
    2. DC voltage
    Source
    Range
    Maximum output span
    Resolution
    Accuracy (% of reading + Counts)
    ETX-1815
    ETX-2015
    100mV
    -15mV-99.999mV
    0.001mV
    0.05+20
    0.02+20
    100mV-125mV
    0.01mV
    0.05+2
    0.02+2
    10V
    0-11V
    0.001V
    0.05+2
    0.02+2
    -10
    C
    -18
    C
    , +28
    C
    -55
    C
    temperature coefficient,±0.005%FS/
    C
    .
    Maximum load: 1mA or 1kΩ (It should be based on the lower load.)
    3. DC mA Measurement
    Range
    Maximum measurement range
    Resolution
    Accuracy (% of reading + Counts)
    ETX-1815
    ETX-2015
    20mA
    0-24mA
    0.001mA
    0.05+2
    0.02+2
    -10
    C
    -18
    C
    , +28
    C
    -55
    C
    temperature coefficient,±0.005%FS/
    C
    .
    Input resistance: <100Ω.
    4. DC mA
    Source
    Range
    Maximum output range
    Resolution
    Accuracy (% of reading + Counts)
    ETX-1815
    ETX-2015
    20mA
    0-24mA
    0.001mA
    0.05+2
    0.02+2
    20mA
    (Transducer simulation)
    0-24mA
    0.001mA
    0.05+2
    0.02+2
    -10
    C
    -18
    C
    , +28
    C
    -55
    C
    temperature coefficient, ±0.005%FS/
    C
    .
    Maximum load voltage: 20V, equivalent to voltage of 20mA on 1000Ω load resistance.
    5. Frequency Measurement
    Range
    Maximum measurement range
    Resolution
    Accuracy (% of reading + Counts)
    ETX-1815
    ETX-2015
    100Hz
    1-99.999Hz
    0.001Hz
    0.02+1
    0.01+1
    1000Hz
    100-999.99Hz
    0.01Hz
    10kHz
    1k-9.9999kHz
    0.1Hz
    100kHz
    10k-99.999kHz
    1Hz
    Sensitivity: 10Hz-10kHz, Vp-p>=1V; the rest: Vp-p>=2V.
    Wave form:
    5 counting points should be added to errors of other wave forms. Commercial frequency can be measured directly.
    6. Frequency
    Source
    Range
    Maximum output range
    Resolution
    Accuracy (% of reading + Counts)
    ETX-1815
    ETX-2015
    200Hz
    0-200Hz
    0.01Hz
    0.02+1
    0.01+1
    2000Hz
    0-2000Hz
    0.1Hz
    20kHz
    0-20kHz
    1Hz
    Output amplitude: >=4.5Vp-p

    Wave form: Square wave
    Accessories:
    1. Test leads (one set)
    2. Alligator clip (one set)
    3. One 12V/1A power adaptor
    4. PDF manual
    Optional accessories:
    6 R03-model rechargeable batteries
    1 Metal Box
    Communication line