-40%

Hantek Process Calibrator HT824 site calibration industry instruments equipment

$ 369.49

Availability: 100 in stock
  • Refund will be given as: Money Back
  • Return shipping will be paid by: Buyer
  • Power supply: 7.4V/7800mAh Lithium battery
  • Item must be returned within: 30 Days
  • Condition: New
  • Country/Region of Manufacture: China
  • All returns accepted: Returns Accepted
  • Natures 2: high stability process calibrator
  • Restocking Fee: No
  • Application Field: Industry and Laboratory
  • MPN: HT824
  • Calibrator Type: Process Calibrator
  • Natures: High accuracy process calibrator
  • Brand: Hantek

    Description

    Hantek HT824  Process Calibrator
    HT824 multifunctional process calibrator has high accuracy, high stability, can be widely used in site calibration of industry instruments and equipment in laboratory. Powerful functions, it can simulate to output voltage in millivolt and volt, current in milliampere, and many types of electric signals needed by the measurement and control during industry control process. It can also test or simulate kinds of TC and RTD signals.
    Features
    5 1/2 digit input/output display.
    Manual/auto cold junction compensation and setting.
    The temperature value can be directly measured/output.
    Auto power off when the voltage of battery is low.
    Apply advanced built-in battery management system. 7.4V/7800mAh lithium battery, which can easily last for over 8 hours during site measurement work.
    Auto triangular wave/step wave signal output.
    It can store 8 sets of measurement and output data, and recall it to display. All the setting value and the function in the last operation can be saved automatically after power-off.
    The screen shows the connection diagram of probes and plugs to avoid wrong operation. It has backlight.
    The output has manual/auto step and slope output function. It can arbitrarily set the value of 0%, 25%, 100% in the range of signal output to test the response speed of transmitter.
    Application field:
    measurement and calibration of instruments,
    maintenance and overhaul of temperature instruments,
    automatically maintenance and overhaul,
    project construction debugging,
    detection and diagnosis of control system signal source,
    configuration of site instrument repairmen room, matching of the thermal engineering laboratory in electric power industry
    Specification.
    Model
    HT824
    DC Voltage Measurement
    Range
    0-30.000V

    Upper part of screen

    *1
    0-24.000V

    Bottom of screen

    *2
    0-90.000mV
    Resolution
    0.001V
    0.001V
    0.001mV
    Accuracy
    0.1%+5
    0.05%+5
    0.05%+5
    *1

    *2

    Input resistance is greater than
    1MΩ
    DC Voltage Output
    Range
    0—20.000V
    0—90.000mV
    Resolution
    0.001V
    0.001mV
    Accuracy
    0.05%+5
    0.05%+5
    Millivolt measurement and output
    *1
    Range
    -10.000mV—80.000mV
    Resolution
    0.001mV
    Accuracy
    0.05%+5
    *1 Press TC(16) to select this function. Signal is at thermocouple micro input/output TC port.
    DC Current (milliampere) Measurement
    Range
    0—24.000mA

    Upper part of screen

    *1
    0—24.000mA

    Bottom of screen

    *2
    Resolution
    0.001mA
    0.001mA
    Accuracy
    0.05%+5
    0.05%+5
    DC Current (milliampere) Output
    Range
    0—24.000mA
    Resolution
    0.001mA
    Accuracy
    0.05%+5
    SIMU

    Simulation

    When outputting current, external voltage is greater than
    12V, less than 28V.
    SOUR

    Source

    When outputting current, signal driving ability is
    1000Ω in 20mA.
    Resistance Measurement
    Ohm Range
    0—400.00Ω
    400.0—4000.0Ω
    Accuracy
    ±Ω
    4
    Wire

    4W

    0.02%+5
    0.02%+5
    2
    Wire

    2W

    and
    3
    Wire

    3W

    0.05%+5
    0.05%+5
    Excitation current

    0.2mA

    Maximum input voltage

    30V

    2
    Wire

    Do not include wire resistance.
    3
    Wire

    Assume to use the matched testing wire, the total resistance cannot be greater than
    100Ω.
    Resistance output
    Range
    5.00Ω―400.00Ω
    400.0―1500.0Ω
    Excitation current from the measurement instrument
    0.15mA-2mA
    0.05mA-0.8mA
    Accuracy
    ±Ω
    0.05%+5
    0.05%+5
    Resolution
    0.1Ω
    0.1Ω
    Temperature - Thermocouple
    Type
    Range
    Resolution
    Measurement and output accuracy
    ±

    S
    -50.0

    to
    0

    0.1

    /0.1

    2

    0

    to
    500.0

    0.1

    /0.1

    1.5

    500.0

    to
    1760.0

    0.1

    /0.1

    1.3

    R
    -50.0

    to
    0

    0.1

    /0.1

    2

    0

    to
    500.0

    0.1

    /0.1

    1.5

    500.0

    to
    1760.0

    0.1

    /0.1

    1.3

    B
    200

    to
    800

    1

    /1

    2.5

    800

    to
    1800

    1

    /1

    2.3

    K
    -200.0

    to
    1370.0

    0.1

    /0.1

    1.3

    N
    -200.0

    to
    1300.0

    0.1

    /0.1

    1.3

    E
    -200.0

    to
    1000.0

    0.1

    /0.1

    1

    J
    -200.0

    to
    1200.0

    0.1

    /0.1

    1

    T
    -200.0

    to
    400.0

    0.1

    /0.1

    1

    Thermocouple adopts
    ITS-90
    If open cold junction compensation, there should be additional
    ±0.5

    Temperature – Thermal resistance
    Type
    Accuracy
    ±

    Range
    Testing 4 wire

    Testing 2 wire and 3 wire

    Output

    Pt100-385
    -200.0

    -850.0

    0.8

    1

    0.8

    Pt100-3926
    -200.0

    -850.0

    0.8

    1

    0.8

    Pt100-JIS
    -200.0

    -850.0

    0.8

    1

    0.8

    Pt200-385
    -200.0

    -250.0

    0.7

    0.8

    0.7

    250.0

    -630.0

    1.3

    2.1

    1.3

    Pt500-385
    -200.0

    -500.0

    0.8

    1.1

    0.8

    500.0

    —630.0

    1

    1.5

    1

    Pt1000-385
    -200.0

    -100.0

    0.7

    0.7

    0.8

    100.0

    -630.0

    0.7

    0.8

    0.8

    Cu100
    -50.0

    -150.0

    1

    1.2

    1

    Cu50
    -50.0

    -150.0

    1

    1.2

    1

    Resolution
    : 0.1°C, 0.1°F
    Allowable excitation current(output)
    : Pt100-385, Pt100-392, Pt100-JIS, Pt200-385:0.15
    to
    3.0 mA
    Pt500-385:0.05
    to
    0.80mA;Pt1000-385:0.05
    to
    0.40mA
    2
    Wire

    Do not include wire resistance.
    3
    Wire

    Assume to use the matched testing wire, the total resistance cannot be greater than
    100Ω.
    Comprehensive Index
    Operation temperature
    0

    to
    50

    Storage temperature
    -20

    to
    70

    Operation  height
    Average elevation 3000 meters below.
    Relative humidity (No condensation relative work humidity
    %)
    75%(30

    to
    40

    )
    45%(40

    to
    50

    )
    35%(50

    to
    55

    )
    <10

    , no control
    Stability
    Out of the range 23±5

    , each degree increase
    ±0.005% of the range.
    Vibration
    The random vibration
    , 2g,5 to 500Hz
    Security
    EN 61010-1:1992
    Protection Level
    Pollution grade

    Product Image
    Package contents
    Shipping:
    We will ship all items within 1-3 working days upon receipt of payment,our goal is: send faster and been received earlier .
    Standard Shipping: To USA,UK and Australia by ePacket,need 7-12 working days.
    Expedited/Standard Int'l Shipping by Fedex,DHL,TNT and EMS courier: To USA,need 3-6 business days,To other countries,need 4-8 business days normally.
    But someti
    mes int'l delivery is highly depended on the courier company and local customs/duties.
    Import duties and taxes are not included in the item price or shipping charges.These charges are the buyer responsibility.
    Warranty&Return Policy:
    We encourage all customers to communicate with us through eBay messages. If you have any questions or comments whatsoever regarding our products or listing, we are waiting to hear from you
    A 1 year warranty is offered for this product.If the product malfunctioned under proper usage per instructions
    manual within the warranty period, please contact us to obtain shipping instructions and send it back at your shipping costs.
    30 days evaluation and investigation takes placed after receiving your return item.A brand new replacement unit will be sent to you at our shipping costs if it meets our warranty