-40%
Hantek Process Calibrator HT824 site calibration industry instruments equipment
$ 369.49
- Description
- Size Guide
Description
Hantek HT824 Process CalibratorHT824 multifunctional process calibrator has high accuracy, high stability, can be widely used in site calibration of industry instruments and equipment in laboratory. Powerful functions, it can simulate to output voltage in millivolt and volt, current in milliampere, and many types of electric signals needed by the measurement and control during industry control process. It can also test or simulate kinds of TC and RTD signals.
Features
5 1/2 digit input/output display.
Manual/auto cold junction compensation and setting.
The temperature value can be directly measured/output.
Auto power off when the voltage of battery is low.
Apply advanced built-in battery management system. 7.4V/7800mAh lithium battery, which can easily last for over 8 hours during site measurement work.
Auto triangular wave/step wave signal output.
It can store 8 sets of measurement and output data, and recall it to display. All the setting value and the function in the last operation can be saved automatically after power-off.
The screen shows the connection diagram of probes and plugs to avoid wrong operation. It has backlight.
The output has manual/auto step and slope output function. It can arbitrarily set the value of 0%, 25%, 100% in the range of signal output to test the response speed of transmitter.
Application field:
measurement and calibration of instruments,
maintenance and overhaul of temperature instruments,
automatically maintenance and overhaul,
project construction debugging,
detection and diagnosis of control system signal source,
configuration of site instrument repairmen room, matching of the thermal engineering laboratory in electric power industry
Specification.
Model
HT824
DC Voltage Measurement
Range
0-30.000V
(
Upper part of screen
)
*1
0-24.000V
(
Bottom of screen
)
*2
0-90.000mV
Resolution
0.001V
0.001V
0.001mV
Accuracy
0.1%+5
0.05%+5
0.05%+5
*1
和
*2
:
Input resistance is greater than
1MΩ
DC Voltage Output
Range
0—20.000V
0—90.000mV
Resolution
0.001V
0.001mV
Accuracy
0.05%+5
0.05%+5
Millivolt measurement and output
*1
Range
-10.000mV—80.000mV
Resolution
0.001mV
Accuracy
0.05%+5
*1 Press TC(16) to select this function. Signal is at thermocouple micro input/output TC port.
DC Current (milliampere) Measurement
Range
0—24.000mA
(
Upper part of screen
)
*1
0—24.000mA
(
Bottom of screen
)
*2
Resolution
0.001mA
0.001mA
Accuracy
0.05%+5
0.05%+5
DC Current (milliampere) Output
Range
0—24.000mA
Resolution
0.001mA
Accuracy
0.05%+5
SIMU
(
Simulation
)
When outputting current, external voltage is greater than
12V, less than 28V.
SOUR
(
Source
)
When outputting current, signal driving ability is
1000Ω in 20mA.
Resistance Measurement
Ohm Range
0—400.00Ω
400.0—4000.0Ω
Accuracy
±Ω
4
Wire
(
4W
)
0.02%+5
0.02%+5
2
Wire
(
2W
)
and
3
Wire
(
3W
)
0.05%+5
0.05%+5
Excitation current
:
0.2mA
。
Maximum input voltage
:
30V
。
2
Wire
:
Do not include wire resistance.
3
Wire
:
Assume to use the matched testing wire, the total resistance cannot be greater than
100Ω.
Resistance output
Range
5.00Ω―400.00Ω
400.0―1500.0Ω
Excitation current from the measurement instrument
0.15mA-2mA
0.05mA-0.8mA
Accuracy
±Ω
0.05%+5
0.05%+5
Resolution
0.1Ω
0.1Ω
Temperature - Thermocouple
Type
Range
Resolution
Measurement and output accuracy
±
℃
S
-50.0
℃
to
0
℃
0.1
℃
/0.1
℉
2
℃
0
℃
to
500.0
℃
0.1
℃
/0.1
℉
1.5
℃
500.0
℃
to
1760.0
℃
0.1
℃
/0.1
℉
1.3
℃
R
-50.0
℃
to
0
℃
0.1
℃
/0.1
℉
2
℃
0
℃
to
500.0
℃
0.1
℃
/0.1
℉
1.5
℃
500.0
℃
to
1760.0
℃
0.1
℃
/0.1
℉
1.3
℃
B
200
℃
to
800
℃
1
℃
/1
℉
2.5
℃
800
℃
to
1800
℃
1
℃
/1
℉
2.3
℃
K
-200.0
℃
to
1370.0
℃
0.1
℃
/0.1
℉
1.3
℃
N
-200.0
℃
to
1300.0
℃
0.1
℃
/0.1
℉
1.3
℃
E
-200.0
℃
to
1000.0
℃
0.1
℃
/0.1
℉
1
℃
J
-200.0
℃
to
1200.0
℃
0.1
℃
/0.1
℉
1
℃
T
-200.0
℃
to
400.0
℃
0.1
℃
/0.1
℉
1
℃
Thermocouple adopts
ITS-90
If open cold junction compensation, there should be additional
±0.5
℃
Temperature – Thermal resistance
Type
Accuracy
±
℃
Range
Testing 4 wire
℃
Testing 2 wire and 3 wire
℃
Output
℃
Pt100-385
-200.0
℃
-850.0
℃
0.8
℃
1
℃
0.8
℃
Pt100-3926
-200.0
℃
-850.0
℃
0.8
℃
1
℃
0.8
℃
Pt100-JIS
-200.0
℃
-850.0
℃
0.8
℃
1
℃
0.8
℃
Pt200-385
-200.0
℃
-250.0
℃
0.7
℃
0.8
℃
0.7
℃
250.0
℃
-630.0
℃
1.3
℃
2.1
℃
1.3
℃
Pt500-385
-200.0
℃
-500.0
℃
0.8
℃
1.1
℃
0.8
℃
500.0
℃
—630.0
℃
1
℃
1.5
℃
1
℃
Pt1000-385
-200.0
℃
-100.0
℃
0.7
℃
0.7
℃
0.8
℃
100.0
℃
-630.0
℃
0.7
℃
0.8
℃
0.8
℃
Cu100
-50.0
℃
-150.0
℃
1
℃
1.2
℃
1
℃
Cu50
-50.0
℃
-150.0
℃
1
℃
1.2
℃
1
℃
Resolution
: 0.1°C, 0.1°F
Allowable excitation current(output)
: Pt100-385, Pt100-392, Pt100-JIS, Pt200-385:0.15
to
3.0 mA
Pt500-385:0.05
to
0.80mA;Pt1000-385:0.05
to
0.40mA
2
Wire
:
Do not include wire resistance.
3
Wire
:
Assume to use the matched testing wire, the total resistance cannot be greater than
100Ω.
Comprehensive Index
Operation temperature
0
℃
to
50
℃
Storage temperature
-20
℃
to
70
℃
Operation height
Average elevation 3000 meters below.
Relative humidity (No condensation relative work humidity
%)
75%(30
℃
to
40
℃
)
45%(40
℃
to
50
℃
)
35%(50
℃
to
55
℃
)
<10
℃
, no control
Stability
Out of the range 23±5
℃
, each degree increase
±0.005% of the range.
Vibration
The random vibration
, 2g,5 to 500Hz
Security
EN 61010-1:1992
Protection Level
Pollution grade
Ⅱ
Product Image
Package contents
Shipping:
We will ship all items within 1-3 working days upon receipt of payment,our goal is: send faster and been received earlier .
Standard Shipping: To USA,UK and Australia by ePacket,need 7-12 working days.
Expedited/Standard Int'l Shipping by Fedex,DHL,TNT and EMS courier: To USA,need 3-6 business days,To other countries,need 4-8 business days normally.
But someti
mes int'l delivery is highly depended on the courier company and local customs/duties.
Import duties and taxes are not included in the item price or shipping charges.These charges are the buyer responsibility.
Warranty&Return Policy:
We encourage all customers to communicate with us through eBay messages. If you have any questions or comments whatsoever regarding our products or listing, we are waiting to hear from you
A 1 year warranty is offered for this product.If the product malfunctioned under proper usage per instructions
manual within the warranty period, please contact us to obtain shipping instructions and send it back at your shipping costs.
30 days evaluation and investigation takes placed after receiving your return item.A brand new replacement unit will be sent to you at our shipping costs if it meets our warranty