-40%
Fluke 725US-NIST Multifunction Process Calibrator,
$ 1832.15
- Description
- Size Guide
Description
Untitled DocumentFluke 725US-NIST Multifunction Process Calibrator,
Model:
725US-NIST
| Order No:
725US-NIST
Easily source and measure a wide variety of process parameters and test many process devices. This unit is capable of measuring and sourcing mA, volts, temperature (RTDs and thermocouples), frequency, ohms, and pressure, using optional pressure modules.
Brand:
Fluke
Model:
725US-NIST
Order No:
725US-NIST
Condition:
NEW
Description
Fluke 725US-NIST Multifunction Process Calibrator,
Format->drawDescription($name, $product ); ?>
Features
Powerful, easy-to-use field calibrator
Measures volts, mA, pressure, RTDs, thermocouples, frequency, and ohms to test sensors and transmitters
Sources/simulates volts dc, mA, thermocouples , RTDs, frequency, ohms, and pressure to calibrate transmitters
Measures/sources pressure using any of 50 750P Pressure Modules (sold separately)
Easy to read measure/source screen displays input and output simultaneously
Powers transmitters during test using loop supply with simultaneous mA measurement
Handles fast pulsed RTD transmitters and PLCs, with pulses as short as 10 ms
Provides a backlit display to provide better visibility in poor light
Features small, streamlined shape, and rugged, reliable design that stands up to field use
Sources mA with simultaneous pressure measurement to conduct valve and I/P tests
Supports flow meter testing with frequency and CPM functions
Performs fast linearity tests with auto-step and auto-ramp features
Included
Process Calibrator
Format->drawIncluded($name, $product ); ?>
Test Leads
Test Clips
Stackable Test Leads
Users Manuals
Statement of Quality Assurance Practices
CE and CSA Markings
Specifications
Measurement Accuracy
Voltage DC
30.000 V: 0.02% + 2 counts (upper display)
30.000 V: 0.02% + 2 counts (lower display)
100.00 mV: 0.02% + 2 counts
-10.00 to 75.00 mV: 0.025% + 1 count (via TC connector)
Current DC
24.000 mA: 0.02% + 2 counts
Resistance
0.0 to 400.0 &ohm: 0.1 &ohm (4-wire), 0.15 &ohm (2- and 3-wire)
401 to 1500 &ohm: 0.5 &ohm (4-wire), 1 &ohm (2- and 3-wire)
1500 to 3200 &ohm: 1 &ohm (4-wire), 1.5 &ohm (2- and 3-wire)
Frequency
2.0 to 1000.0 CPM: 0.05% + 1 count
1.0 to 1100.0 Hz: 0.05% + 1 count
1.00 to 10.00 kHz: 0.05% + 1 count
Sensitivity: 1 V peak-to-peak-minimum
Pressure
Accuracy from 0.025% of range using any of 29 pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure.
Source Accuracy
Voltage DC
100.00 mV: 0.02% + 2 counts
10.000 V: 0.02% + 2 counts
-10.00 to 75.00 mV: 0.025% + 1 count (via TC connector)
Current DC
24.000 mA (source): 0.02% + 2 counts
24.000 mA (simulate): 0.02% + 2 counts
Resistance
15.0 to 400.0 &ohm: 0.15 &ohm (exc. current 0.15 to 0.5 mA), 0.1 &ohm (exc. current 0.5 to 2 mA)
401 to 1500 &ohm: 0.5 &ohm (excitation current 0.05 to 0.8 mA)
1500 to 3200 &ohm: 1 &ohm (excitation current 0.05 to 0.4 mA)
Frequency
2.0 to 1000.0 CPM: 0.05%
1.0 to 1100.0 Hz: 0.05%
1.00 to 10.00 kHz: 0.25%
Waveform: 5 V p-p squarewave, -0.1 V offset
RTDs and Thermocouples
Measure Accuracy
NI-120: 32.36°F (0.2°C)
PT-100 (385): 32.6°F (0.33°C)
PT-100 (393): 32.54°F (0.3°C)
PT-100 (JIS): 32.54°F (0.3°C)
PT-200 (385): 32.36°F (0.2°C)
PT-500 (385): 32.54°F (0.3°C)
PT-1000 (385): 32.36°F (0.2°C)
Resolution: 0.1°C
J: 33.26°F (0.7°C)
K: 33.44°F (0.8°C)
T: 33.44°F (0.8°C)
E: 33.26°F (0.7°C)
R: 35.24°F (1.8°C)
S: 34.7°F (1.5°C)
B: 34.52°F (1.4°C)
L: 33.26°F (0.7°C)
U: 33.35°F (0.75°C)
N: 33.62°F (0.9°C)
Resolution: J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F
XK: 33.08°F (0.6°C)
BP: 34.16°F (1.2°C)
Source Accuracy
NI-120: 32.36°F (0.2°C)
PT-100 (385): 32.6°F (0.33°C)
PT-100 (393): 32.54°F (0.3°C)
PT-100 (JIS): 32.54°F (0.3°C)
PT-200 (385): 32.36°F (0.2°C)
PT-500 (385): 32.54°F (0.3°C)
PT-1000 (385): 32.36°F (0.2°C)
Resolution: 0.1°C
Accuracy stated for 4-wire measurement
J: 33.26°F (0.7°C)
K: 33.44°F (0.8°C)
T: 33.44°F (0.8°C)
E: 33.26°F (0.7°C)
R: 34.52°F (1.4°C)
S: 34.7°F (1.5°C)
B: 34.52°F (1.4°C)
L: 33.26°F (0.7°C)
U: 33.35°F (0.75°C)
N: 33.62°F (0.9°C)
Resolution: J, K, T, E, L, N, U: 0.1°C, B, R, S: 1°C
XK: 33.08°F (0.6°C)
BP: 34.16°F (1.2°C)
Functions Specifications
Ramp Functions
Source functions: Voltage, current, resistance, frequency, temperature
Ramps: Slow ramp, Fast ramp, 25% step-ramp
Loop Power Function
Voltage: 24 V
Accuracy: 10%
Maximum current: 22 mA, short circuit protected
Step Functions
Source functions: Voltage, current, resistance, frequency, temperature
Steps: 25% of range, 100% of range
Environmental Specifications
Operating Temperature
14 to 131°F (-10 to 55°C)
Storage Temperature
-4 to 159.8°F (-20 to 71°C)
Operating Altitude
9842.52' (3000 m)
Mechanical and General Specifications
Batteries
4 x AA alkaline batteries
Battery Replacement
Separate battery compartment, accessable without breaking calibration seal
Side Port Connections
Pressure module connector, also used for remote real-time programming
Dimensions
5.1 x 9.3 x 2.4" (130 x 236 x 61 mm)
Weight
1.43 lbs (0.65 kg)
Safety Specifications
Agency Approvals
EN 61010-1:1993, ANSI/ISA S82.01-1994; CAN/CSA C22.2 No 1010.1:1992
Terms & Conditions
Item Condition:
Unless specified otherwise all products listed are Brand New in the original factory packaging and include a full factory warranty.
Shipping:
We currently only ship to U.S. buyers. We ship items within one or two business days from payment. We do not process shipments on weekends and holidays. Local pick up is not available. We only ship to addresses verifiable by either PayPal or credit card issuing bank.
Please note that we cannot alter the address once a purchase is made. In the case of PayPal payment, we will ship orders when the payment is marked “Eligible” for PayPal Seller’s protection.
*Shipping Rates are for Continental US, Please Contact us for other US Destinations
Payment:
Currently all payments must be made directly though PayPal
Sales Tax:
We are required to charge sales tax in North Carolina
Return Policy:
If for any reason you are not 100% satisfied with a product you receive from us, you may return the regular stock product within 30 days from the time of receipt, for a full refund or exchange of the product you purchased (less any shipping costs). Within this time, products may be returned; freight prepaid and must be in their original packaging and in resalable condition.
Shipping errors, missing items or damages must be reported to us immediately (damages should be accompanied by a signed bill of lading acknowledging the damage). Items returned will be inspected for damage or misuse at which time they may be subject to restocking fees, other fees or refused, prior to the issuance of any credit.