-40%
Fluke 5500A-SC600 Multifunction Calibrator with 600MHz Scope Module
$ 21668.62
- Description
- Size Guide
Description
The Fluke 5500A is a revolutionary product that addresses a wide cross-section of your electrical calibration work load. It sources direct voltage and current, alternating voltage and current with multiple waveforms and harmonics, two simultaneous voltage outputs or voltage and current, and simulates power with phase control, resistance, capacitance, thermocouples and RTDs. The 5500A's Oscilloscope Calibration options provide level sine wave, fast edge, time mark and amplitude signals for calibration of oscilloscopes up to 600 MHz.The 5500A was designed to cover a very wide range of medium accuracy electrical measurement devices including:
Handheld and bench multimeters
Oscilloscopes and ScopeMeter Test Tools
Wattmeters
Analog volt/ohm/amp/watt instruments
Electronic thermometers
Data loggers
Strip chart recorders
XY Recorders
Power harmonics analyzers
Process calibrators
Current clamps
And related instruments
Option SC600 (Included):
The SC600 enables the versatile 5500A and the enhanced performance 5520A to calibrate nearly all your scopes fully up to 600 MHz. The 600 MHz 5500A-SC600 is a dramatically enhanced version of our popular 300 MHz 5500A-SC300 option
Technical Specifications
Voltage DC
Range:
0 to ±1020V
Best 1 Year Specification:
±50 ppm of setting
Current DC
Range:
0 to ±11A
Best 1 Year Specification:
±0.01% of setting
Resistance
Range:
0 to 3.29.999 MΩ
Best 1 Year Specification:
±0.009% of setting
Voltage AC
Range:
1 mV to 1020V
10 Hz to 500 kHz, Sine
Best 1 Year Specification:
±0.03% of setting
Current AC
Range:
29 m A to 11A
10 Hz to 10 kHz, Sine
Best 1 Year Specification:
±0.06% of setting
Capacitance
Range:
0.33 nF to 1.1 mF
Best 1 Year Specification:
±0.25% of setting
Thermocouple Source and Measure
Range:
-250°C to +2316°C (11 types)
Best 1 Year Specification:
± 0.14°C of setting
RTD Source
Range:
-200°C to +630°C
(8 types)
Best 1 Year Specification:
±0.03°C of setting
DC Power
Range:
109 mW to 11 kW
Best 1 Year Specification:
± 0.08% of setting
AC Power
Range:
109 mW to 11 kW
45-65 Hz, PF=1
Best 1 Year Specification:
± 0.15% of setting
Phase
Range:
0 to ± 179.99°
Best 1 Year Specification:
±0.15°
Frequency
Range:
0.01 Hz to 2.0 MHz
Best 1 Year Specification:
±25 ppm of setting
General Specifications
Warm up Time
Twice the time since last warmed up, to a maximum of 30 minutes
Settling Time
Less than 5 seconds for all functions and ranges except as noted
Standard Interfaces
IEEE-488 (GPIB), RS-232, 5725A (5500A only)
Temperature Performance
Operating:
0°C to 50°C
Calibration:
(tcal): 15°C to 35°C
Storage:
-20°C to 70°C
Temperature Coefficient
Temperature coefficient for temperatures outside tcal ± 5°C is 10% of the 90-day specification (or 1-year, as applicable) per °C
Relative Humidity
Operating:
< 80% to 30°C, < 70% to 40°C, < 40% to 50°C
Storage:
< 95%, non-condensing
Altitude
Operating:
3,050m (10,000 ft) maximum
Non-operating:
12,200m (40,000 ft) maximum
Safety
Designed to comply with IEC 1010-1 (1992-1); ANSI/ISA-S82.01-1994; CAN/CSA-C22.2 No. 1010.1-92
Analog Low Isolation
20V
EMC
Designed to comply with FCC Rules Part 15
Line Power
Line Voltage (selectable):
100V, 120V, 220V, 240V
Line Frequency:
47 to 63 Hz
Line Voltage Variation:
: ± 10% about line voltage setting
Power Consumption
300 VA
Calibration Documentation
17025 accredited report of calibration included
Dimensions
Height:
17.8 cm (7 in), standard rack increment, plus 1.5 cm (0.6 in) for feet on bottom of unit
Width:
43.2 cm (17 in), standard rack width
Depth:
47.3 cm (18.6 in) overall
Weight (without options)
20 kg (44 lbs.)
Absolute Uncertainty Definition
5500A and 5520A uncertainty specifications include stability, temperature coefficient, linearity, line and load regulation, and the traceability of the external standards used for calibration. You do not need to add anything to determine the total uncertainty of your calibrator for the temperature range indicated.
Specification Confidence Interval
> 99%
General Specifications for the Oscilloscope calibration option
DC Voltage
Ranges:
0 to ±6.6V (50Ω)
0 to ±33V (1 MΩ)
Best 1 Year Specification:
±0.05%
AC Voltage (Squarewave)
Ranges:
±1 mV to ±6.6V p-p (50Ω)
±1 mV to ±130V p-p (1 MΩ)
Best 1 Year Specification:
±0.25%
Fast Edge
Ranges:
4 mV to 2.5V p-p (50Ω)
Best 1 Year Specification:
=300 ps Rise Time
Leveled Sinewave
Ranges:
50 kHz to 600 MHz 50 kHz to 300 MHz
Best 1 Year Specification:
±1.5% Flatness
Time Markers
Ranges:
5s to 2 ns
Spike, square, 20% pulse, sine
Best 1 Year Specification:
±2.5 ppm
Wave Generator
Ranges:
10 mV to 2.5V amplitude1.8 mV to 55V p-p (1 MΩ)
1.8 mV to 2.2V p-p (50Ω)
10 Hz to 100 kHz
Square, Sine, Triangle
Best 1 Year Specification:
±3%
Pulse Generator
Ranges:
10 mV to 2.5V amplitude
4 ns to 500 ns width
20 ms to 150 ns period
Best 1 Year Specification:
±5%
±2.5 ppm
TV Trigger
NTSC, SECAM, PAL, PAL-M
Input Impedance Measurement
Range:
40Ω to 1.5 MΩ
Best 1 Year Specification:
±0.1% ±0.1%
Range:
5 pF to 50 pF
Best 1 Year Specification:
±5%
Overload Measurement
5V to 9V (dc or ac squarewave), 5 to 60 seconds
Included Items:
This sale does not include probes, cables, manuals, power cords or any other accessories unless otherwise stated or pictured.