-40%

FLUKE 5440B DIRECT VOLTS CALIBRATOR W/ 5440A CALIBRATOR PROCEDURE STORAGE MODULE

$ 765.6

Availability: 100 in stock
  • Condition: Clean and Tested
  • Brand: Fluke
  • All returns accepted: ReturnsNotAccepted
  • MPN: 5440B

    Description

    FLUKE 5440B DIRECT VOLTS CALIBRATOR W/ 5440A CALIBRATOR  MODULE
    The
    5440B
    direct voltage calibrator is equipped with bright displays for clear visibility at any viewing angle. The 5440B is easy to use because the 40-character, alphanumeric display provided in addition to the numeric output display, makes operating instructions and error messages clear and readable in engineering units and English messages instead of coded numerics.
    For semi-automated testing, the 5440B lets a complete test sequence of up to 60 steps be stored in the internal Procedure Storage memory and recorded for later use in the interchangeable plug-in Procedure Storage modules. A test sequence is recalled and executed one step at a time with each touch of the NEXT STEP key.
    The excellent accuracy specifications for the 5440B are easily maintained in any lab by performing the simple automatic calibration procedures, which store the calibration constants in non-volatile memory. No hardware adjustments are required.
    Full accuracy over extended temperature range of 10°C
    Completely automatic internal calibration—no mechanical adjustments
    Simplified 5-minute external calibration to traceable standards
    Procedure Storage module for single button test setup
    Completely programmable through the GPIB/IEEE-488 interface
    Serial printer output for calibration constants and instrument test results
    Output voltage: 0 to 1100 V
    Output current: 0 to 60 mA up to 22 V, except divided outputs: 0 to 25 mA up to 1100 V
    Uncertainty specification: ±(PPM of Output + Microvolts) for 90 days
    0 V to 11 V: 2.0 +5 µV
    11 V to 22 V: 2.0 + 8 µV
    22 V to 275 V: 3.5 + 100 µV
    275 V to 1100 V: 3.5 + 400 µV
    Divided output 0 V to 220 mV: 5 + 0.5 µV
    Divided output 0.22 V to 2.2 V: 4.5 + 1.0 µV
    Output stability: ±(PPM of Output + Microvolts) for 30 days. Specifications apply for initial stabilization of two hours, constant ambient temperature of ±1°C, constant line voltage, constant load, and measurement bandwidth of 0.1 Hz to 1 Hz
    0 V to 11 V: 0.5 +3 µV
    11 V to 22 V: 0.5 + 4.5 µV
    22 V to 275 V: 1.0 + 60 µV
    275 V to 1100 V: 1.0 + 300 µV
    Divided output 0 mV to 220 mV: 2 + 0.3 µV
    Divided output 0.22 V to 2.2 V: 2 + 0.7 µV
    Resolution
    0 V to 11 V: 1 µV
    11 V to 22 V: 1 µV
    22 V to 275 V: 10 µV
    275 V to 1100 V: 100 µV
    Divided output 0 V to 220 mV: 0.01 µV
    Divided output 0.22 V to 2.2 V: 0.1 µV
    Output noise at 10 Hz to 10 kHz bandwidth
    0 mV to 220 mV: 5 µV
    0.22 V to 2.2 V: 15 µV
    0 V to 11 V: 30 µV
    11 V to 22 V: 50 µV
    22 V to 275 V: 150 µV
    275 V to 1100 V: 300 µ
    V
    We strive to give you 5-Star Service, so please contact us regarding any problems BEFORE filing any claims or leaving unfavorable feedback. We will do our best to resolve any issues.
    International buyers please contact us for shipping quotes and arrangements prior to purchase.
    We buy all brands of telephone systems and phones. Please turn your used telephone equipment into cash by contacting us.
    Quoted shipping is to lower 48 states. Shipping to Alaska, Hawaii, and Puerto Rico will have a extra charge.