-40%

DC Current Voltage 0-20mA/5V Frequency Process Calibrator & Multimeter 2in1 VC78

$ 136.75

Availability: 100 in stock
  • Return shipping will be paid by: Buyer
  • Item must be returned within: 30 Days
  • Brand: victor
  • Model: VC78
  • Condition: New
  • All returns accepted: Returns Accepted
  • Country of Manufacture: China
  • Restocking Fee: No
  • Refund will be given as: Money Back
  • Country/Region of Manufacture: China
  • MPN: VC78

    Description

    Process calibrator and Multimeter 2 in 1
    VC78
    1. Multimeter functions: can measure DCV, ACV, DCmV, Ohm, DCA, ACA, Frequency,
    Duty circle, Continuity and Diode test.
    2. Process calibrator functions: can
    output DCmV, DCV, Frequency, Analog transducer XMT and DCmA.
    3. 0.2% basic accuracy for output and measurement.
    4. Can show mA and value % at the same time when output DCA; 25% and 100% auto step,
    manual step and auto ramp for current output.
    5. Power and backlight off automatically.
    6. Comply with
    IEC 61010-1, 2000
    Overvoltage category II

    Max. input voltage:AC/DC600V

    Pollution degree 2
    Packing list:
    Test leads, a pair;
    Fuse, 2pcs;
    Manual
    Multimeter specifications:
    Range
    Measuring Range
    Resolution
    Accuracy
    DCV
    4V
    -4.000V~4.000V
    1mV
    0.2%+4
    40V
    -40.00V~40.00V
    0.01V
    0.2%+4
    400V
    -400.0V~400.0V
    0.1V
    0.2%+4
    ACV
    (40Hz~500Hz)
    (5%~100%RANG)
    400mV
    0~400.0mV
    0.1mV
    1%+4
    4V
    0~4.000V
    1mV
    0.5%+4
    40V
    0~40.00V
    0.01V
    0.5%+4
    400V
    0~400.0V
    0.1V
    0.5%+4
    DCmV
    40mV
    -40.00 mV~40.00mV
    0.01mV
    0.2%+4
    400mV
    -400.0mV~400.0mV
    0.1mV
    0.2%+4
    OMH
    400Ω
    0~400.0Ω
    0.1Ω
    0.2%+4
    4KΩ
    0~4.000KΩ

    0.2%+4
    40KΩ
    0~40.00KΩ
    0.01 KΩ
    0.2%+4
    400KΩ
    0~400.0KΩ
    0.1 KΩ
    0.2%+4
    4MΩ
    0~4.000MΩ
    1 KΩ
    0.2%+4
    40MΩ
    0~40.00MΩ
    0.01 MΩ
    1%+4
    DCA
    40mA
    -40.00mA~40.00mA
    0.01mA
    0.2%+4
    400mA
    -400.0mA~400.0mA
    0.1mA
    0.2%+4
    ACA
    (40Hz~500Hz)
    (5%~100%RANG)
    40mA
    0~40.00mA
    0.01mA
    0.5%+4
    400mA
    0~400.0mA
    0. 1mA
    0.5%+4
    FREQ
    50Hz
    0~50.0Hz
    0.01Hz
    0.1%+3
    500Hz
    0~500.0Hz
    0.1Hz
    0.1%+3
    5KHz
    0~5.000kHz
    1Hz
    0.1%+3
    50KHz
    0~50.00kHz
    0.01KHz
    0.1%+3
    100KHz
    0~100.0kHz
    0.1KHz
    0.1%+3
    Duty cycle ratio
    0.1%~99%
    0.1%
    1%
    Diode test
    1V
    0.001V
    10%
    Continuity
    ≤50ΩBB
    0.1Ω
    Output specifications:
    Range
    Setting
    Range
    Resolution
    Accuracy
    DCmV
    500mV
    -50.0mV~550.0mV
    0.1mV
    0.5%+6
    DCV
    5V
    -0.500V~5.500V
    1mV
    0.2%+4
    FREQ
    100Hz
    1.0Hz~110.0Hz
    0.1Hz
    0.2%+2
    1KHz
    0.100KHz~1.100KHz
    0.001KHz
    0.2%+2
    10KHz
    1.0KHz~11.0KHz
    0.1KHz
    0.2%+2
    Analog transducer XMT
    -20mA
    0~-22.00mA
    0.01mA
    0.2%+4
    DCmA
    20mA
    0~22.00mA
    0.01mA
    0.2%+4