-40%

1nA-100mA 10mkV-1000V 0.02% P320 Calibrator Voltage&Current Standard an-g. GR

$ 1167.11

Availability: 33 in stock
  • Model: P320
  • Condition: New – Open box
  • Brand: P320

    Description

    P320 Multivalued Programable Voltage & Current Calibrator analog of FLUKE,EDC,Agilent,Tektronix
    IET Labs, but has the same or better characteristics:
    P320
    calibrator
    provides:
    -
    calibrated
    voltage
    range
    10
    -5
    - 1000 V;
    -
    calibrated
    current
    range
    10
    -9
    - 10
    -1
    A;
    - remote
    management, including setting
    limits
    and the level of
    the output parameters;
    - level control
    of
    the output parameter
    in
    BCD
    8-4-2-1;
    Power supply:
    220V, 50 Hz;
    Power consumption
    :
    500
    VA;
    The average service
    10 years;
    Dimensions
    488х535х250
    mm;
    Weight
    26 kg.
    Warranty 12 month.
    Programmable
    Calibrator
    P320
    is a precision source of
    calibrated
    voltage and current
    with possibility of manual and
    program control
    and is designed
    to be used
    in automated
    calibration
    facilities
    , as well
    as a separate
    device for verification
    of
    analog and digital
    devices in DC.
    The ability of remote
    ,
    manual and
    program control
    (mode selection
    , setting
    limit of
    output parameter
    and values of calibrated
    voltage or current)
    allows to use
    programmable
    calibrator
    P320
    in automated
    measurement systems
    and calibration
    devices.  Calibrator
    is designed for operation
    at temperatures of 10° to 35 °C and relative
    humidity of
    80%
    at 25 °C.
    Calibrators
    designed
    for areas with
    tropical climate
    (marked as
    -
    P320
    04.1
    **
    ), should
    operate
    in air-conditioned rooms
    at temperature
    10-35 °C.
    Calibrator
    Power supply

    in
    AC
    220 V,
    frequency 50 Hz
    ,
    on request
    export type of
    programmable
    calibrator
    P320
    may
    be constructed
    for 60 Hz
    frequency.
    Technical
    characteristic
    s
    Programmable
    calibrator
    P320
    provides
    at local
    (manual)
    and program
    (
    remote) control:
    issuance of
    calibrated
    voltage in range
    from
    10
    -5
    to 10
    3
    V
    (calibrated
    voltage
    mode
    ,
    CV)
    ;
    issuance of calibrated
    current in
    range from
    10
    -9
    to 10
    -1
    (calibrated
    current
    mode
    , CC)
    at program (
    remote) control
    setting
    limit
    and output parameter level is carried out in
    accordance with
    Tables 1 and 2
    , control of
    output parameter level
    is carried out in
    binary-
    decimal code
    8-4-2-1
    .
    Calibrator’s turn on and
    turn off
    are provided by commands
    "Start"
    and "
    Reset"
    in accordance
    with Table 3
    .
    Calibrator’s output turn off is provided by
    command "
    Reset" or
    in emergency situations with the presence of
    logical unit
    on the contact
    "
    P"
    jack
    YP
    .
    Acceptable basic error of calibrated values in current and voltage calibration mode and acceptable basic error values of voltage and current calibration
    after zero level setup and calibration
    corresponds to those shown in the Table 4.
    Acceptable basic error limit
    is
    indicaded
    when
    device is
    calibrated
    at a normal
    element
    class 0.001 and
    for load
    not exceeding
    10%
    of a permissible one.
    Acceptable basic error limit
    is
    preserved for
    at least 2 hours
    after calibration.
    Calibration with the
    less
    accurate normal
    element is allowed
    (or
    ION
    ), and
    permissible basic error limit will be increased
    on value ΔU (ΔI),
    defined by formula
    :
    ΔU = ΔU
    ne
    · А
    , μV (1),
    or
    ΔI = ΔU
    ne
    · А · 10
    -3
    , μA (2),
    where
    ΔU
    ne

    difference between
    basic errors of
    applied
    normal element
    class
    0.001
    μV;
    A
    – value,
    numerically equal to
    calibrator’s max limit
    in V or
    mA.
    Instability of
    calibrated
    current (voltage
    )
    for 8 hours
    of
    continuous work without
    zero
    adjustment
    and calibration
    is
    equal to
    values shown
    in Table 5. Instability of calibrated
    o
    utput
    voltage (current)
    for 3 months without
    zero
    adjustment
    and calibration
    (except limit of 100
    mV)
    does not exceed
    values shown
    in Table 5. For
    range of 100 mV
    the shown values
    a
    re guaranteed
    , if
    zero is adjusted every day.
    Calibrator’s acceptable additional error limit in working condition at external temperature for every 10
    °C is equal to
    :
    in CV mode -
    acceptable basic error
    limit
    ;
    in CC
    mode
    -
    value
    (1
    10
    -4
    ·

    + 1 · 10
    -5
    ·
    In
    ),
    where:
    Ik
    -
    set
    value of
    calibrated
    current
    , mA;
    In -
    current value,
    corresponding to
    max limit
    , mA.
    Acceptable additional error
    limit,
    caused by changes in voltage
    supply for
    ± 22
    V from nominal, is equal to
    :
    (
    1 · 10
    -4
    ·

    + 1 · 10
    -5
    ·
    Un
    ) -
    for
    range 100
    mV
    and 1
    V;
    (
    1 · 10
    -5
    ·

    + 1 · 10
    -6
    ·
    Un
    ) –
    for the rest
    calibrated
    voltage ranges
    ;
    (
    1 · 10
    -5
    ·
    In
    ) -
    all
    calibrated
    currents ranges
    , where:
    Uk
    -
    value of
    calibrated
    voltage
    , V;
    Un -
    voltage
    corresponding to
    max
    limit
    , V.
    Calibrator’s
    operation mode setup time
    is
    not more than 1
    hours.
    Calibrator’s continuous operation
    time without
    setting an operation mode in operating conditions
    is at least 8
    hours per day
    .
    The level of
    the effective value of
    the variable component
    at calibrator’s output does not exceed
    the values shown
    in Table
    6.
    Acceptable value
    of current load in CV
    mode
    :
    200 mA-for voltage up to 150 V;
    40 mА - for voltage up to 300 V;
    30 mА - for voltage up to 600 V;
    15 mА - for voltage up to 1000V.
    Acceptable value
    of voltage load
    in CV
    mode
    - 100V.
    Programmable
    Calibrator
    P320
    has
    a overload safety device
    .
    Safety device
    switches off
    the calibrator’s
    output
    within the
    current
    load (220-240) mA -
    for voltage
    up to 150
    V, (55-60)
    mA
    - for
    other values and for
    (1170
    ± 10
    ) V.
    The

    RESET” indicator lights,
    when
    protection mode is activated
    .
    When
    the voltage
    exceeds
    175
    V,
    a high voltage
    indicator turns on
    .
    Programmable Calibrator P320
    has the output voltage (current) limit. Setup time for calibrated voltage, in the range from 0.1 to 100 V – 5 sec.; from 100 to 1000 V - 10 sec., with an error not exceeding the values
    shown in Table 4. Maximum acceptable additional output voltage error caused by the changes in current load from 10 to 100% of permissible values in the CC mode is the limit of basic error in the range of "100 mV" and half of the basic error limit for the rest of the calibrated voltage ranges.
    The insulation between the case and isolated electric circuits stands for 1 minute of the test voltage effect, shown in Table 7.
    The insulation resistance between the case and isolated electric circuits does not exceed the values shown in Table. 7. Programmable Calibrator P320 is warm resistant at 60 ° C and cold resistant at minus 50 °C. Calibrator’s network power supply with the nominal voltage does not exceed
    150 V•A.
    Calibrator’s dimensions do not exceed 488x535x250 mm. Calibrator’s weight is
    not more than 26 kg.
    At the customer request schema and configuration instructions may be sent.
    Table 1.
    Comand name
    Connectors contact
    8 ·10
    -1
    Un (In)
    B
    4 ·10
    -1
    Un (In)
    B
    2 ·10
    -1
    Un (In)
    G
    1 ·10
    -1
    Un (In)
    D
    8 ·10
    -2
    Un (In)
    E
    4 ·10
    -2
    Un (In)
    G
    2 ·10
    -2
    Un (In)
    3
    1 ·10
    -2
    Un (In)
    I
    8 ·10
    -3
    Un (In)
    K
    4 ·10
    -3
    Un (In)
    L
    2 ·10
    -3
    Un (In)
    M
    1 ·10
    -3
    Un (In)
    H
    8 ·10
    -4
    Un (In)
    5
    4 ·10
    -4
    Un (In)
    6
    2 ·10
    -4
    Un (In)
    7
    1 ·10
    -4
    Un (In)
    8
    8 ·10
    -5
    Un (In)
    9
    4 ·10
    -5
    Un (In)
    10
    2 ·10
    -5
    Un (In)
    11
    1 ·10
    -5
    Un (In)
    15
    8 ·10
    -6
    Un (In)
    16
    4 ·10
    -6
    Un (In)
    18
    2 ·10
    -6
    Un (In)
    19
    1 ·10
    -6
    Un (In)
    21
    Table 2.
    Calibrated
    voltage or current limit set command
    100 mV
    1 V
    10 V
    100 V
    1000 V
    1 mA
    10 mA
    100 mA
    Connectors contact YP
    C
    F
    T
    X
    X, T
    Y
    Y, T
    Y, X
    Table 3.
    Signal command name
    Connectors contact YP
    “Start” – sets the calibrator into a working condition
    A
    “RESET”
    - Resets
    the direction
    of
    the output calibrator’s clamps
    P
    Note:
    1.
    Commands
    are provided with a logical signal
    "I".
    All signals
    are given on a common wire
    (
    contact "0"
    connector
    YP
    ).
    2
    .
    On the
    output clamps
    in the "
    Reset" mode there is
    a
    voltage of
    reverse polarity up
    to 5
    V from
    a source with a
    capacity of
    not more than
    10-5 W.
    3
    .
    A signal
    of logical
    "0
    " corresponds to
    the voltage level
    from minus
    0.8 to
    plus
    0.4V.
    4.
    Logical
    signal
    "I"
    corresponds to
    the voltage level
    from 2.4 to
    5.25 V.
    5
    .
    Name command shown in
    table.
    It
    is expressed by the installed option value
    in units
    of the chosen calibrated
    voltage
    (
    Up) or
    current (
    Ip) l
    imit
    .
    Table 4.
    Calibrated voltage (current) limits
    Basic accuracy limits of calibrated voltage
    Acceptable accuracy limits of calibrated voltage (current)
    100 mV
    ±(0,04 · Uк + 10) μV
    ±(0.05 · Uк + 10) μV
    1 V
    ±(20 · Uк + 10) μV
    ±(30 · Uк + 10) μV
    10 V
    ±(10 · Uк + 40) μV
    ±(20 · Uк + 40) μV
    100 V
    ±(30 · Uк + 500) μV
    ±(40 · Uк + 500) μV
    1000 V
    To 600 V
    ±(0.03 · Uк + 5) mV
    ±(0.04 · Uк + 5) mV
    More 600 V
    ±(0.04 · Uк + 5) mV
    ±(0.05 · Uк + 5) mV
    1 mA
    ±(0.02 · Iк + 0.01) μA
    ±(0.06 · Iк + 0.01) μA
    10 mA
    ±(0.05 · Iк + 0.1) μA
    ±(0.1 · Iк + 0.1) μA
    100 mA
    ±(0.05 · Iк + 1) μA
    ±(0.1 · Iк + 1) μA
    Note
    :
    I.
    Uk
    (
    Ik)
    -
    a dimensionless quantity
    numerically
    equal to the calibrated
    voltage value
    in mV
    at the limit of
    100mV,
    in volts
    - for
    the rest of
    the ranges of
    calibrated current values
    in
    mA
    .
    Table 5.
    Voltage (current) Calibrated limits
    Output voltage (current) instability
    For 8 hours
    For 3 months
    100 mV
    ±(0.02 · Uк + 15) μV
    20 μV
    1 V
    ±(20 · Uк + 15) μV
    200 μV
    10 V
    ±(20 · Uк + 15) μV
    1 mV
    100 V
    ±(0.03 · Uк + 1.5) mV
    15 mV
    1000 V
    To 600 V
    ±(0.05 · Uк + 15) mV
    0.2 V
    More than 600 V
    ±(0.1 · Uк + 15) mV
    0.2 V
    1 mA
    ±(0.05 · Iк + 0.0015) μA
    0.2 μA
    10 mA
    ±(0.1 · Iк + 0.015) μA
    2 μA
    100 mA
    ±(0.1 · Iк + 1.5) μA
    20 μA
    Table 6.
    Calibrated voltage limits
    Variable component in the line, μV
    Up to 0.3 Hz
    Up to 100 kHz
    Up to 1 MHz
    100 mV
    ± 5
    300
    500
    1 V
    ± 5
    300
    500
    10 V
    ± 20
    300
    500
    100 V
    ± 200
    1 · 10
    3
    2 · 10
    3
    1000 V
    ± 2 · 10
    3
    5 · 10
    3
    1 · 10
    4
    Table 7.
    Parts of calibrator’s schemes
    between which
    the insulation resistance
    is measured
    and
    dielectric strength is tested
    Insulation resistance
    , Ω,
    at least
    Testing voltage, kV
    DC
    AC, 50 Hz,
    effective value
    First section
    Second section
    1. Combined output clams «1», «2», «3»,
    «4»
    Clamp «E»
    10
    9
    -
    -
    2. Combined output clams «1», «2», «3»,
    «4»
    Clamp «╧»
    10
    9
    3.0
    -
    3. Clamp «╧»
    10
    9
    1.5
    -
    4. Network 220 V
    10
    8
    -
    1.5
    Accuracy of the calibrator II320 (P320,
    П
    320) in the different ranges:
    Calibrated Voltage limits (currents)
    Error limits of calibrated voltage values (currents)
    Max. permissible error for calibrated voltages (currents)
    100
    mV
    ±(0,04*Uк + 10)
    mkV
    ±(0,05*Uк + 10)
    mkV
    1
    V
    ±(20*Uк + 10)
    mkV
    ±(30*Uк + 10)
    mkV
    10
    V
    ±(10*Uк + 40)
    mkV
    ±(20*Uк + 40)
    mkV
    100
    V
    ±(30*Uк + 500)
    mkV
    ±(40*Uк + 500)
    mkV
    100
    V -
    600
    V
    ± (0,03*Uк + 5)
    mV
    ±(0,04*Uк + 5)
    mV
    More
    600
    V
    ±(0,04*Uк + 5)
    mV
    ±(0,05*Uк + 5)
    mV
    1
    mA
    ±(0,02*Iк + 0,01)
    mkA
    ±(0,06*Iк + 0,01)
    mkA
    10
    mA
    ±(0,05*Iк + 0,1)
    mkA
    ±(0,1*Iк + 0,01)
    mkA
    100
    mA
    ±(0,05*Iк + 1)
    mkA
    ±(0,1*Iк + 1)
    mkA
    This device was also used in USSR and Russian army. So it has best quality
    ,
    longevity, and permanence characteristic.
    Condition:
    NEW (not used, but from an old stock). Tested and 100% workable.
    If necessary, the device can be calibrated and provided with the calibration certificate
    from Government Standardization Institute ( +145-265usd).
    P320 Multivalued Programable Voltage & Current Calibrator
    is analog
    device of such manufactures as
    FLUKE,EDC,Agilent, LEEDS & NORTHRUP, ESI (Electro Scientific Industries), Honeywell, IET Labs, JAME G BIDDLE CO, GRAY INST, TEGAM, Guildline, Tektronix, Fluke and others.
    Also we can provide other resistance, capacitance and inductance standards, decade box and other etalons.
    Please take a look on my other items!
    If you haven’t found the needed item in my listing, please contact me. I’ll try to help you.
    Technical characteristics:
    P320
    is a precision
    calibrator of
    voltages and currents
    Temperature
    10-35 ° C;
    Relative humidity
    up to 80%;
    Atm. pressure
    84-106,7 kPa (630-800 mmHg).
    This device  can be also named as:
    P320, P-
    320
    , P
    320
    , R
    320
    , R
    320
    , R-
    320
    , р
    320
    , р-
    320
    , р
    320
    ,
    П
    320,
    П
    -320,
    П
    320, II320 II 320 II-320,
    calibrator, standart calibrator, controller, programable calibrator,
    voltage calibrator, current calibrator.
    Photos
    If necessary we can take photos of a device from various angles.
    Technical Documentation
    In case you didn't find in technical specifications for the device all necessary information you are interested in, feel free to contact me.  I will look through the technical documentation for the device and I will be happy to consult you.
    Also I may speak directly with the manufacturer and find out more specific information about this product.
    If some technical parameters for the device (error, accuracy, measuring range, operating voltage and frequency) do not meet your requirements, please, e-mail me and I will negotiate with the manufacturer whether it is possible to deliver you a device on the desired specifications without a cost increase and in the shortest time.
    On delivering the device, electric circuit diagrams and all technical documentation for operation, calibration and maintenance will be supplied. Also there will be documents that testify the accuracy and compliance with specifications.
    In addition, translation of technical documentation into the customer’s language may be discussed.
    Delivery set
    On delivering the device will be completely ready for use.
    There are all necessary cables, adapters, sensors and spare parts as envisaged in technical documentation. Hence, there is no point in purchasing any additional repair & measurement equipment.
    Warranty
    Warranty of this item
    - 12  month.
    Before sending a device, all devices are checked whether they comply with all technical specifications.
    Highly qualified metrology engineers carry out the check-up of every instrument at a specialized laboratory and with the help of master gages.
    If necessary, we can send you photos or video with the check-up process.
    I ship only fully working devices complying with all parameters.
    The warranty for this device is 1 year from the date of shipment from my warehouse.
    Within 1 year term I will provide the repair of the device for free in case of manufacturing defect or when the technical parameters do not comply with technical documentation. You will have to pay only for delivery.
    When a device is out of order due to your fault (its fall, it is flooded with water, the power supply does not meet the specified technical requirements, input signals exceed the norm, etc.) or there are conspicuous marks of casing opening (broken warranty labels), it is considered a non-warranty repair.
    Within 1 year term we can advise you for free on the device operation.
    After-warranty service
    After warranty termination I can arrange a paid repair and technical maintenance of a device as well as I can sell you all necessary spare parts for repair at minimum prices. I always have them in stock.
    Packaging
    Immediately after checking, the device will be wrapped in several layers of strong air-bubble film and placed into a strong cardboard box. Extra cardboard plates will be used for fixation.
    If necessary, wooden box or pallet may be used. For a more reliable fixation foam can be applied. The whole box will be placed in a waterproof polyethylene bag which will be wound with several layers of packing tape.
    A special handle will be made for ease of transportation.
    Thus, I guarantee qualitative and conscientious packing of the device that reduces to minimum the possibility of damage during transportation.
    Discount (from-10% to -90%)
    I suggest you a device which is unique in its class and price category with the following specifications: (accuracy, measurement range, error, temperature operating conditions), endurance and durability (military performance, aluminum, stainless steel, titanium or carbolite casing, shock and vibration resistance, high maintainability and reliability), free measuring kit (cables, adapters, load, fuses, etc.), 1year warranty.
    Unused cheap devices with the same specifications, accuracy and durability do not exist.
    If you consider the price for this device unreasonably high, and you know the similar equipment at a lower price, please, let me know.
    I will help you to compare these two models. In case your model (which is cheaper) is the same as the device I suggest or even it is better, then
    I guarantee to sell you a unit at that cheaper price with additional 10% discount.
    Shipping details:
    Please, mind that I ship from Ukraine (Europe, +2), so that the shipping time may differ from your local time.
    I send goods via AirMailpost.
    App. delivery time :
    Europe – 7-15 days;
    USA, Japan&others – 10-20 days (depends on a country).
    I will ship in 10-15 business days after payment clearance.
    The goods may also be delivered by the express mail services such as DHL, UPS, FedEx, TNT or EMS.
    With express delivery you will mostly receive your goods within 3-7 working days.
    Payment details:
    I expect payment in 4 days after the auction ends.
    I accept a PayPal payment as the safest way of payment (preferably).
    If you do not have a PayPal account you can pay by wire transfer to my credit card.
    Other variants of payment are acceptable, for example in case of pickup way of shipping, i can accept cash payment.
    (This will be an official purchase on eBay).
    Please, tell me if you cannot pay in time, we can always negotiate it.
    When purchasing a few items, you’ll save on shipping.
    Return policy:
    I accept refunds and returns. If there is something wrong with the device, please, inform me within 5 days after receiving it.
    I will refund your costs or send you the other item, as you wish (
    after I receive the previous item
    ).
    Please only serious bidders!